Métodos biometrológicos para avaliação, in vivo, da hidratação de diferentes cremes comerciais contendo 10% de ureia em seu claim principal

dc.contributor.authorChaves, César Augusto Cecílio
dc.contributor.authorD'Agostino, Marcelle Chamie
dc.contributor.authorBaby, André Rolim
dc.contributor.authorSilva, Vânia Rodrigues Leite e
dc.date.accessioned2014-09-16T15:19:10Z
dc.date.available2014-09-16T15:19:10Z
dc.date.issued2014
dc.description.abstractAs medidas biometrológicas referentes à hidratação cutânea e à perda de água transepidérmica são parâmetros importantes para avaliação da capacidade hidratante de cremes e loções indicados para tal finalidade. Este trabalho teve como objetivo principal a análise, através de testes biometrológicos, da performance hidratante de cinco tradicionais cremes do mercado que possuem a concentração de 10 % de ureia como seu claim principal. Analisou-se a quantidade de água no estrato córneo através do Corneometer®, equipamento que utiliza o princípio de capacitância para medir a hidratação cutânea; e a perda de água transepidérmica, através do TEWLmeter®, equipamento que mede a taxa de evaporação da água pela pele. Às medidas biometrológicas obtidas, foram aplicados testes do tipo t-Student, a partir dos quais ficou demonstrada a existência de diferenças significativas entre as performances de hidratação dos cremes analisados. O creme identificado como “D” demonstrou melhor capacidade hidratante e melhor prevenção da perda de água transepidérmica. Os resultados mostraram a importância da realização testes de equivalência também para produtos de aplicação tópica, uma vez que, conforme demonstrado neste estudo, apesar de alguns produtos conterem a mesma substância ativa, diferenças na composição de seus veículos podem alterar sua efetividade.pt
dc.description.abstractThe biometrological measurements of skin hydration and transepidermal water loss are important parameters to evaluate the moisturizing ability of creams and lotions suitable for this purpose. This study analyzed, through biometrological tests, the performance of five different commercial moisturizing creams containing 10.0 % urea. The amount of water in the stratum corneum was analyzed by Corneometer®, equipment that measures the skin hydration by capacitance principle. The transepidermal water loss was analyzed by TEWLmeter®, equipment that measures water evaporation through the skin. Student t-tests were applied to these measures, which demonstrated significant differences between the hydration performances of the moisturizing creams analyzed. The moisturizer identified as "D" showed a better moisturizing ability and better prevented transepidermal water loss. Overall, results showed the importance of testing equivalence for topical products, since, as demonstrated in this study, although certain products may contain the same active substance, differences in their vehicles’ composition can alter the effectiveness.en
dc.formatapplication/pdf
dc.identifier.issn2182-2360
dc.identifier.urihttp://hdl.handle.net/10437/5512
dc.language.isoporpt
dc.language.isoeng
dc.publisherEdições Lusófonaspt
dc.rightsopenAccess
dc.subjectPELEpt
dc.subjectPRODUTOS COSMÉTICOSpt
dc.subjectSKINen
dc.subjectCOSMETICSen
dc.subjectCIÊNCIAS FARMACÊUTICASpt
dc.subjectPHARMACEUTICAL SCIENCESen
dc.subjectHIDRATAÇÃOpt
dc.subjectHYDRATIONen
dc.subjectESTUDOS DE CASOpt
dc.subjectCASE STUDIESen
dc.subjectPERDA TRANSEPIDÉRMICA DE ÁGUApt
dc.subjectTRANSEPIDERMAL WATER LOSSen
dc.subjectUREIApt
dc.subjectUREAen
dc.titleMétodos biometrológicos para avaliação, in vivo, da hidratação de diferentes cremes comerciais contendo 10% de ureia em seu claim principalpt
dc.titleBiometrological methods to evaluate in vivo the skin hydratation of different commercial moisturizers containing 10.0% urea as the main claimen
dc.typearticlept

Ficheiros

Principais
A mostrar 1 - 1 de 1
Miniatura indisponível
Nome:
biometrological_methods_evaluate.pdf
Tamanho:
430.6 KB
Formato:
Adobe Portable Document Format
Licença
A mostrar 1 - 1 de 1
Miniatura indisponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: