Avaliação de dose em radiologia pediátrica numa unidade de cuidados intensivos neonatal

dc.contributor.authorCardoso, Susana Cristina de Sousa
dc.contributor.authorHilário, Joana
dc.contributor.authorMatela, Nuno
dc.contributor.authorPereira, Paulo Marques
dc.date.accessioned2012-03-24T15:45:07Z
dc.date.available2012-03-24T15:45:07Z
dc.date.issued2009
dc.descriptionRevista Lusófona de Ciências e Tecnologias da Saúdept
dc.description.abstractA radiossenssibilidade em crianças é superior à dos adultos, pelo que a avaliação dos parâmetros de dose utilizados em pediatria, principalmente em recém-nascidos, assume particular importância. Também importante é a avaliação da quantidade de dose de radiação a que os pacientes, pelo simples facto de estarem perto, ou na vizinhança, de outros que vão realizar exames radiológicos, estão sujeitos. Neste estudo, efectuado no Hospital D. Estefânia em Lisboa, avaliou-se a dose de radiação ionizante com dosímetros (ATOMTEX 3509B) no paciente examinado e no paciente adjacente. Foram calculadas as doses à entrada da pele (DEP) utilizando os parâmetros físicos empregados. Nos 28 exames efectuados por 8 técnicos diferentes, as leituras obtidas com os dosímetros eram praticamente insignificantes, quer para o paciente examinado (énero feminino e 0.04 énero masculino) quer para o adjacente (0 ). Os valores de DEP calculados estavam abaixo do limite recomendado internacionalmente para recém-nascidos, de 80 μGy. Apesar de haver uma diferença estatisticamente significativa entre os pesos das crianças do género masculino e feminino, não se verificou uma diferença semelhante para as DEP calculadas. Este estudo demonstrou que a DEP calculada com os parâmetros físicos utilizados ficava abaixo da DEP recomendada internacionalmente, e que as leituras obtidas nos pacientes examinados, bem como no paciente adjacente, atingiram níveis insignificantes.pt
dc.description.abstractRadio-sensitivity in children is much larger than in adults. Hence, x-ray examinations in newborns staying in Neonatal Intensive Care Units (NICU's) is a concern. Simultaneously, given the close proximity of neighboring patients in NICU's, x-ray examinations can have repercussions on adjacent patients, In this study, carried out at the D. Estefânia Pediatric Hospital in Lisbon, Portugal, the dose of ionizing radiation administered to newborns undergoing the examination was evaluated using dosimeters (ATOMTEX 35 O9B), as well as in the adjacent patient. Entrance skin doses (ESD) were calculated given the physical parameters registered during each examination. In the 28 examinations performed by 8 different technicians, dosimeter readings were practically insignificant, both for the examined patient (0.09 uSv for female gender e 0.04 uSv to the male gender) as well as for the adjacent patient (O uSv). Calculated ESD values were all below the intemationally recommended value of 80 uGy. Although a statistically significant difference was observed between the weights of male and female patients, no such difference was identified in the calculated ESD values. This study showed that the ESD calculated with the physical parameters used in the examinations were below the intemationally recommended ESD and those dosimeters readings in both examined and adjacent patient reached insignificant levels.en
dc.formatapplication/pdf
dc.identifier.issn1646-3854
dc.identifier.urihttp://hdl.handle.net/10437/2146
dc.language.isoporpt
dc.publisherEdições Universitárias Lusófonaspt
dc.rightsopenAccess
dc.subjectMEDICINApt
dc.subjectMEDICINEen
dc.subjectRADIOLOGIA PEDIÁTRICApt
dc.subjectPEDIATRIC RADIOLOGYen
dc.subjectDOSE DE RADIAÇÃOpt
dc.subjectRADIOTHERAPY DOSAGEen
dc.subjectRAIOS Xpt
dc.subjectX-RAYSen
dc.subjectCUIDADOS INTENSIVOSpt
dc.subjectINTENSIVE CAREen
dc.subjectNEONATOLOGIApt
dc.subjectNEONATOLOGYen
dc.subjectRADIAÇÃO IONIZANTEpt
dc.subjectIONIZING RADIATIONen
dc.subjectESTUDOS DE CASOpt
dc.subjectCASE STUDIESen
dc.titleAvaliação de dose em radiologia pediátrica numa unidade de cuidados intensivos neonatalpt
dc.titleDose evaluation in pediatric radiology at a neonatal intensive care uniten
dc.typearticlept

Ficheiros

Principais
A mostrar 1 - 1 de 1
Miniatura indisponível
Nome:
726-2601-1-PB.pdf
Tamanho:
242.65 KB
Formato:
Adobe Portable Document Format
Licença
A mostrar 1 - 1 de 1
Miniatura indisponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: