Avaliação dos níveis de referência de dose no estudo tomográfico do tórax

dc.contributor.authorSantos, Daniel
dc.contributor.authorCustódio, Nélson
dc.contributor.authorMadeira, Paula
dc.contributor.authorMatela, Nuno
dc.date.accessioned2020-02-04T18:37:55Z
dc.date.available2020-02-04T18:37:55Z
dc.date.issued2011
dc.descriptionBiomedical and biopharmaceutical research : jornal de investigação biomédica e biofarmacêuticapt
dc.description.abstractEste estudo foi realizado num Hospital, em Lisboa, onde foram avaliados 30 exames tomográficos de tórax. Com a realização deste trabalho, pretendeu-se quantificar o nível de referência de dose num dos equipamentos de TC de um Hospital de Lisboa, incidindo na avaliação do estudo do tórax. Pretendeu-se ainda, quantificar um valor médio para as grandezas dosimétricas em tomografia computorizada, nomeadamente o CTDIw, DLP e dose efectiva e, comparar postenormente, os valores obtidos, com osníveis de referência de diagnóstico regulamentados pelo ICRP. O nível de referência de dose obtido do Hospital, para os exames estudados foi 1 3,67 mGy. A média de CTDIw foi 12,18 mGy, a média de DLPcorrespondeu a 291,49 mGy.cm e, amédia de dose efectiva apurada foi 4,95 mSv. Com este estudo constatou-se também, que previsivelmente, existe um risco baixo de ocorrência de cancro ou de efeitos hereditários graves em todos os indivíduos da amostra, e que a dose efectiva recebida em cada exame corresponde, aproximadamente, a uma exposição de radiação equivalentea 2,06 anos de radiação natural.pt
dc.description.abstractThis study was performed in a Hospital m Lisbon, where 30 CT chest scans were evaluated. With this work, we sought to quantify the dose reference level of CT equipment in an hospital focusing the study on the thorax evaluation. It was also intended to quantify an average value for the CT dosimetric quantities, including CTDlw, DLP and effective dose, and then, to compare obtained values with diagnostic reference levels regulated by the ICRP. The dose reference level obtained m the Hospital, for the studied exams was 13, 67 mGy. The average CTDlw was 12, | 8 mGy, the mean DLP corresponded to 291, 49mGy.cm and the average effective dose found was 4, 95 mSv. This study also allowed to conclude, as predicted, that there is a low risk of cancer occurrence or severe congenital effects in all individuals of the studied sample, and that the effective dose received in each test corresponds approximately to a radiation exposure equivalent to 2,06 years of natural radiation. The average value of all dosimetric quantities did not exceed the limits set by the ICRP.en
dc.formatapplication/pdf
dc.identifier.issn2182-2379
dc.identifier.urihttp://hdl.handle.net/10437/10030
dc.language.isoporpt
dc.language.isoeng
dc.publisherEdições Universitárias Lusófonaspt
dc.rightsopenAccess
dc.subjectMEDICINApt
dc.subjectTOMOGRAFIASpt
dc.subjectTÓRAXpt
dc.subjectRADIAÇÃO IONIZANTEpt
dc.subjectRAIOS Xpt
dc.subjectNÍVEIS DE REFERÊNCIA DE DIAGNÓSTICOpt
dc.subjectMEDICINEen
dc.subjectTOMOGRAPHIESen
dc.subjectTHORAXen
dc.subjectIONIZING RADIATIONen
dc.subjectX-RAYSen
dc.subjectRADIOTHERAPY DOSAGEen
dc.subjectDOSE DE RADIAÇÃOen
dc.subjectDIAGNOSTIC REFERENCE LEVELSen
dc.titleAvaliação dos níveis de referência de dose no estudo tomográfico do tóraxpt
dc.titleEvaluation of the reference dose levels in the chest CT scanen
dc.typearticlept

Ficheiros

Principais
A mostrar 1 - 1 de 1
Miniatura indisponível
Nome:
article7_8n1.pdf
Tamanho:
978.54 KB
Formato:
Adobe Portable Document Format
Descrição:
Artigo
Licença
A mostrar 1 - 1 de 1
Miniatura indisponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: