Avaliação dos padrões de dose em radiologia pediátrica na radiografia simples do abdómen

dc.contributor.authorPereira, Alessandra
dc.contributor.authorDuarte, Ana
dc.contributor.authorMatela, Nuno
dc.contributor.authorPereira, Paulo Marques
dc.date.accessioned2012-03-28T14:42:26Z
dc.date.available2012-03-28T14:42:26Z
dc.date.issued2009
dc.descriptionRevista Lusófona de Ciências e Tecnologias da Saúdept
dc.description.abstractA radiossensibilidade de crianças, muito superior à dos adultos, aliada à elevada utilização de exames radiológicos, justifica a preocupação com as doses à entrada da pele (DEP) e doses efectivas (DEF) durante exames radiológicos pediátricos. Neste trabalho quantificou-se a DEP e a DEF em sistemas convencionais e digitais em exames abdominais em crianças dos 0-15 anos, comparando os parâmetros físicos utilizados com os estipulados pelos critérios de boas práticas. Em 35 exames, verificou-se uma diferença estatisticamente significativa (p=0.025) entre DEP convencional (522.78 μGy) e digital (35.29 μGy), o que não ocorreu com a DEF (48.89 vs. 41.35 μGy). Os valores de DEP em sistema convencional ultrapassavam os de referência para os grupos etários de 1-4 (477.5 vs. 400 μGy) e 15 anos (2260 vs. 1200 μGy).A maior parte dos critérios de boas práticas estavam em conformidade com os critérios internacionais, excepto a utilização de filtragem (superior ao recomendado), a utilização inadequada de grelha e a utilização (não recomendada) de controlo automático de exposição em crianças com idade inferior a 5 anos.pt
dc.description.abstractHigher children radio-sensibility and the large usage of radiological examinations justify the concern with entrance skin dose (ESD) and effective dose (EFD) during paediatric radiological examinations. In this study, the ESD and EFD were quantified in both conventional and digital systems, during abdominal exams of children aged 0-15 years. Physical parameters were registered and compared with those established by international guidelines. In a total of 35 cases registered in this study, a statistically significant difference was observed between conventional (522.78 μGy) and digital (35.29 μGy) ESD. No statistical difference was observed between digital and conventional EFD (48.89 vs. 41.35 μGy). Conventional ESD values surpassed those established by international guidelines within the 1-4 (477.5 vs. 400 μGy) and 15 (2260 vs. 1200 μGy) age groups. Most practices were in compliance with guidelines except filter usage (higher than recommended), inadequate grid application, and usage of automatic exposure control (not recommended) in children younger than 5 years of age.en
dc.formatapplication/pdf
dc.identifier.issn1646-3854
dc.identifier.urihttp://hdl.handle.net/10437/2238
dc.language.isoporpt
dc.publisherEdições Universitárias Lusófonaspt
dc.rightsopenAccess
dc.subjectMEDICINApt
dc.subjectMEDICINEen
dc.subjectPEDIATRIC RADIOLOGYen
dc.subjectRADIOLOGIA PEDIÁTRICApt
dc.subjectDOSE DE RADIAÇÃOpt
dc.subjectRADIOTHERAPY DOSAGEen
dc.subjectESTUDOS DE CASOpt
dc.subjectCASE STUDIESen
dc.titleAvaliação dos padrões de dose em radiologia pediátrica na radiografia simples do abdómenpt
dc.titleEvaluation of paediatric dose standards in abdominal x-rayen
dc.typearticlept

Ficheiros

Principais
A mostrar 1 - 1 de 1
Miniatura indisponível
Nome:
1120-3980-1-PB.pdf
Tamanho:
174.42 KB
Formato:
Adobe Portable Document Format
Licença
A mostrar 1 - 1 de 1
Miniatura indisponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: